Sensidyne Gas Detection

SensCast Wireless Gas Detection

Industrial Wireless Fixed Gas Detection Solution

SensCast Wireless Gas Detection

The SensCast gas monitoring system is a cutting edge wireless platform providing the complete solution for gas detection signal communication throughout a plant or facility. SensCast is the versatile and easy to use wireless solution for continuous, multi-point gas monitoring.

 

Comprehensive Solution to Meet Application Requirements

All components available for 900 MHz or 2.4 GHz systems

Remote or locally mounted sensors for ideal detector location

Ultra low-powered transmitters have internal power source

Hazardous area and non-classified area models

Can be used for short-term and permanent installations

 

Safety Reliability without Compromise 

Deployable for facility-wide or local monitoring networks 

Certified for Division 1 and Division 2 hazardous classified areas 

Repeater functions to link wired system from a controller to DCS/PLC

Wireless relays enable control of annunciation and mitigation functions

Dual-sensor models have independent outputs and alarms for each channel

 

User Friendly and Intuitive

Significantly lowers installation costs from running wiring and conduit

Mobile or computer browser access to the system setup and measurements

Easy, menu-driven setup with confirmed signal notification

Relay activation control including three alarm levels, com, and power 

Available survey tool for analyzing signal performance and layout

 

 

Intuitive and Cost Effective Solution for Complex Applications 

SensCast takes a unique approach to solving communication and connectivity challenges found in many gas detection applications. Beginning with proven toxic and oxygen sensors and robust transmitters, SensCast then provides options for linking and communicating sensor measurements, alarm conditions, and faults to local and facility-wide networks, without traditional expensive hard wiring.

The drawings to the right depict common network installations using SensCast to wirelessly communicate within the gas detection system. Wireless systems can be installed indoors or outside with the transmission distance dependent upon many facility-specific factors. Our SensCast Site Survey Tool (SST) calculates network reach and potential RF interferences ensuring optimal setup of your wireless gas detection network.

 

 

 

Drawing 1: SensCast Transmitters transmit wirelessly to the SensCast Receiver. The Receiver sends Transmitter output via wifi or Modbus (wireless or wired). The SensCast Relayer actively “listens” for alarm or fault conditions and activates annunciators or hazard mitigation systems connected to one of 5 relays.



Wireless Gas Detection

Drawing 2: Two independent networks consisting of a Receiver and 32 SensCast Transmitters (or 16 Dual Head Transmitters) exist in one facility. A Sensidyne wireless-enabled controller (Model 7200 shown) collects all 64 outputs sending them to a DCS or PLC via wireless Modbus. A SensCast Relayer actively “listens” for alarm or fault conditions and activates annunciators or hazard mitigation systems.

Filename Filesize
/chroot/home/a70c8823/public_html/Support Library/gas-detection/SensCast
360-0197-01rA SENSCAST Wireless Monitoring System User Manual.pdf 1.85 MB
Sensidyne_SensCast-Data Brochure_5 pg_022620rB_FINAL.pdf 4.24 MB

Sensors

Filename Filesize
/chroot/home/a70c8823/public_html/Support Library/gas-detection/SensCast/Sensors
365-1311-12rA IR CH4 100pc LEL SensCast Data Sheet.pdf 219.76 kB
365-1311-13rA IR C3H8 100pc LEL SensCast Data Sheet.pdf 219.31 kB
365-1401-11rB NH3 50ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1401-12rB NH3 100ppm SF-SensCast Data Sheet.pdf 40.25 kB
365-1401-13rB NH3 300ppm SF-SensCast Data Sheet.pdf 40.25 kB
365-1401-14rB NH3 500ppm SF-SensCast Data Sheet.pdf 40.25 kB
365-1402-11rB Cl2 5ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1402-12rB Cl2 10ppm SF-SensCast Data Sheet.pdf 48.07 kB
365-1402-13rB Cl2 20ppm SF-SensCast Data Sheet.pdf 40.25 kB
365-1402-21rB Cl2-S 5ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1402-22rB Cl2-S 10ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1403-11rB HCN 20ppm SF-SensCast Data Sheet.pdf 40.26 kB
365-1406-11rB H2S 10ppm SF-SensCast Data Sheet.pdf 76.93 kB
365-1406-12rB H2S 50ppm SF-SensCast Data Sheet.pdf 76.93 kB
365-1406-13rB H2S 100ppm SF-SensCast Data Sheet.pdf 76.94 kB
365-1407-11rB HF 10ppm SF-SensCast Data Sheet.pdf 40.26 kB
365-1407-12rB HF 20ppm SF-SensCast Data Sheet.pdf 76.93 kB
365-1408-11rB HCl 10ppm SF-SensCast Data Sheet.pdf 40.26 kB
365-1408-12rB HCl 20ppm SF-SensCast Data Sheet.pdf 40.26 kB
365-1408-13rB HCl 100ppm SF-SensCast Data Sheet.pdf 76.95 kB
365-1410-11rB H2 1000ppm SF-SensCast Data Sheet.pdf 40.2 kB
365-1410-12rB H2 EC 100% LEL SF-SensCast Data Sheet.pdf 40.21 kB
365-1412-11rB AsH3 1ppm SF-SensCast Data Sheet.pdf 40.2 kB
365-1414-11rB SiH4 10ppm SF-SensCast Data Sheet.pdf 40.19 kB
365-1415-11rB F2 10ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1415-12rB F2 25ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1418-11rB SO2 10ppm SF-SensCast Data Sheet.pdf 76.92 kB
365-1418-12rB SO2 20ppm SF-SensCast Data Sheet.pdf 76.92 kB
365-1419-11rB CO 100ppm SF-SensCast Data Sheet.pdf 76.93 kB
365-1419-12rB CO 500ppm SF-SensCast Data Sheet.pdf 76.92 kB
365-1419-21rB CO LI 100ppm SF-SensCast Data Sheet.pdf 40.23 kB
365-1419-22rB CO LI 500ppm SF-SensCast Data Sheet.pdf 40.23 kB
365-1419-23rB CO LI 1000ppm SF-SensCast Data Sheet.pdf 40.23 kB
365-1421-11rB NO2 10ppm SF-SensCast Data Sheet.pdf 40.2 kB
365-1422-11rB Br2 1ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1422-12rB Br2 10ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1439-11rB ClO2 1ppm SF-SensCast Data Sheet.pdf 40.21 kB
365-1439-12rB ClO2 5ppm SF-SensCast Data Sheet.pdf 40.21 kB
365-1440-11rB O2 25% SF-SensCast Data Sheet.pdf 77.13 kB
365-1442-11rB NO 100ppm SF-SensCast Data Sheet.pdf 76.93 kB
365-1443-11rB O3 1ppm SF-SensCast Data Sheet.pdf 76.91 kB
365-1443-12rB O3 2ppm SF-SensCast Data Sheet.pdf 76.91 kB
365-1447-11rB COCl2 1ppm SF-SensCast Data Sheet.pdf 76.91 kB
365-1451-11rB ETO 10ppm SF-SensCast Data Sheet.pdf 40.24 kB
365-1453-11rB MeOH 500ppm SF-SensCast Data Sheet.pdf 40.23 kB